FUSION DEVELOPERS
Proposal · 55 ft x 77 ft PEB Shed (Mono-Slope + Optional Rooftop Solar)
Client: BTI — Venus Pharma · Lahore, Pakistan · 2026-08-01
Structural & Engineering Notes
| Element | Standard |
| Primary steel | A572 Gr50 / ASTM A992 |
| Connections | AISC 360-16 LRFD, AWS D1.1 |
| Loads | ASCE 7-16 (wind 110mph Exp C, seismic SDC C) |
| Footings | ACI 318, f'c 4000 psi, Gr60 rebar |
| Solar load | 4.2 t on roof (if option taken) |
Per FD-QA-HLD-007 (IMRAN, FD-QA-001): column/rafter section sizes for all options are PRELIMINARY for visualization & BOQ only — NOT design-verified. Steel procurement/fabrication released only after PE sign-off (Kamran Ahmed FD-ENG-001 + Rashid Mehmood) confirming AISC 360-16 LRFD, wind 110 mph Exp C, seismic SDC C, rafter camber L/240, connections (25mm base plate, A325, 25mm J-bolts). This is a quality gate, not a scope gap.